November 08, 2021 Service Pack

The following Service Pack versions were released:

Versions (Sensor and Server)

20.2.401

21.1.301

Note

Linux AV is generally available in version 20.2.303 and later. When you upgrade a Linux sensor to this version, and the sensor is assigned a policy with Anti-Malware > Signatures mode enabled, scheduled and on demand scans run automatically according to policy settings. On access scans on Linux machines are enabled by default in version 20.2.462 and later (prior to this version, contact Technical Support to enable on access scans).

The tables below describe the enhancements, fixed issues, and changes included in each version.

  • The Versions column indicates the versions that include the fix.

  • The Required Update column indicates if the fix requires sensor/server update.

IMPORTANT: If you want to upgrade your servers to this version, we recommend that you upgrade all components - Registration server, Detection servers, and WebApp server - to this version.

Version 20.2.401

Issue

Area

Description

Required Update

Sensor OS

CYBR-48695

Sensor Dashboard

On the System > Dashboard screen, machines running Windows 11 are now displayed under the Sensors by OS version section.

Server

N/A

CYBR-40644

Sensor Management

After initial installation, the sensor now reports to the Windows Security Center after the signatures database download is complete. This prevents an unnecessary notification stating virus protection is out of date. If after 4 hours the signatures database download is not complete, the notification stating virus protection is out of date is correctly displayed.

Sensor and server

Windows

CYBR-43628

Sensor Management

On the System > Sensors screen, if you upgraded a sensor on a machine running Windows 2012 to a Hotfix or a Service Pack, the upgrade failed due to a verification issue as a result of a Microsoft update. This issue has been resolved.

Sensor and server

Windows

Version 21.1.301

Issue

Area

Description

Required Update

Sensor OS

CYBR-48695

Sensor Dashboard

On the System > Dashboard screen, machines running Windows 11 are now displayed under the Sensors by OS version section.

Server

N/A

CYBR-40644

Sensor Management

After initial installation, the sensor now reports to the Windows Security Center after the signatures database download is complete. This prevents an unnecessary notification stating virus protection is out of date. If after 4 hours the signatures database download is not complete, the notification stating virus protection is out of date is correctly displayed.

Sensor and server

Windows

CYBR-48349

Malop Management

If you updated a Malop after it was closed, the update was excluded from email notifications. This issue has been resolved.

Server

N/A

CYBR-48124

Malop Management

In version 21.1.281, on the Malop details screen, the Mark as active button did not classify the Malop as active. This issue has been resolved.