June 22, 2021 Service Pack

The following Service Pack versions were released:

Versions (Sensor and Server)

20.2.303

Note

Linux AV is generally available in version 20.2.303 and later. When you upgrade a Linux sensor to this version, and the sensor is assigned a policy with Anti-Malware > Signatures mode enabled, scheduled and on demand scans run automatically according to policy settings. On access scans on Linux machines are supported from version 20.2.462 and above.

The tables below describe the enhancements, fixed issues, and changes included in each version.

  • The Versions column indicates the versions that include the fix.

  • The Required Update column indicates if the fix requires sensor/server update.

IMPORTANT: If you want to upgrade your servers to this version, we recommend that you upgrade all components - Registration server, Detection servers, and WebApp server - to this version.

Enhancements

Issue

Area

Description

Versions

Required Update

Sensor OS

CYBR-42655

Malops management

On the Malops management screen, if you filtered the list of Malops by the time frame filter, only Malops that had been both opened and updated within the selected time frame were displayed. We have updated the time frame filter to only return Malops that were updated within the selected time frame.

20.2.303

Server

N/A

CYBR-43969

NGAV

Scheduled and on demand Signature-based scans are now generally available on machines running Linux sensors. When working with a Linux sensor that is assigned a policy with Anti-Malware > Signatures mode enabled, scheduled and on demand scans run automatically according to policy settings. On access scans are not currently supported.

20.2.303

Sensor

Linux

CYBR-42859

Sensor Management

On the System > Sensors screen, machines running the Windows 20H2 version of Windows are now classified as Windows 10.

20.2.303

Server

N/A

Fixed issues

Issue

Area

Description

Versions

Required Update

Sensor OS

CYBR-43193

Investigation

On the Investigation screen, if you ran a query using the Machine Element, the Time since last communication filter was unable to be applied to the results. This issue has been resolved.

20.2.303

Server

N/A

CYBR-42467

Investigation

On the Malop Details screen, if you selected a file to investigate, the Investigation screen opened without pre-populated filters for the relevant Element. This issue has been resolved.

20.2.303

Server

N/A

CYBR-43387

Malops Management

Email notifications for Endpoint Protection Malops contained an incorrect link to the relevant Malop in the Cybereason platform. This issue has been resolved.

20.2.303

Server

N/A

CYBR-42275

Malops Management

On environments with the newer data infrastructure enabled, the email notification for Endpoint Protection Malops was not sent. This issue has been resolved.

20.2.303

Server

N/A

CYBR-43328

NGAV

In specific modes and cases, reporting of Behavioral document protection alerts on the Cybereason platform was not aligned with the sensor decision and the feature configuration. This issue has been resolved.

20.2.303

Server

N/A

CYBR-43628

Sensor Management

On the System > Sensors screen, if you upgraded a sensor on a machine running Windows Server 2012 to a Hotfix or a Service Pack version, the upgrade failed due to a verification issue as a result of a Microsoft update. This issue has been resolved.

20.2.303

Sensor

Windows

CYBR-40927

Sensor Management

On the System > Sensors screen, if you exported a list of sensors to a CSV file, the OS field in the file was empty for sensors on mobile devices. This issue has been resolved.

20.2.303

Server

N/A

Please see our Legal Disclaimer on links to third party web sites.